Raps Off Grid Solar Specialists
  • Home
  • Containerised 6Kw standalone.
  • Station Master 30 Kilowatt Standalone
  • SUNKING FLA Battery Banks.
  • SUNKING AGM TECHNOLOGY
  • SUNKING GEL Battery Banks
  • Remote solar systems.
  • Contact page.
Sun King FLA Battery Banks, hard working & reliable.
 Batteries for remote power systems with high capacity discharge and recharge needs.
    Specifically formulated for solar, wind, hydro and generator storage applications.


SUN KING flooded lead acid batteries are all 2 volt cells that come in 3 amp hour ratings, 930, 1100 & 1600AHC100 respectively, they are connected in series of 6 for 12 volts, 12 for 24 volts and 24 for 48 volts.  Our recommended standard battery bank is the 1600AH amp hour x 48 volt, it gives tremendous battery capacity storage and instant high power output. 

SUN KING flooded lead acid batteries are very reliable and hard working units when operated within the manufacturers specifications, well cared for they will give up to 15 years of service. All battery banks come with fully rubberised black cables and grey rubberised lock down bolts ( note above photo ) for maximum safety, this ensures little to no risk of short circuit while installing from sockets or spanners. These are high quality vented Flooded Lead Acid modules with a simple flip top lids for adding  pure distilled water for increasing used fluid levels.
 
We can deliver any where in Australia, New Zealand or the South Pacific at purchasers expense or they can be collected from our specialist battery warehouses in Sydney, Brisbane, Melbourne, Adelaide FOB. A two year pro rata warranty comes with all batteries sold, a complete maintenance booklet is supplied for recording voltages and specific gravity levels*. Batteries take 4 days to "wet up and charge" we store them dry so that when you receive your new batteries you are assured that they have not been sitting on a shelf aging. Below are our battery bank prices. To order click "add to cart" or call us on 0411 424 274 or email order to mailto:raps@mail.com

Each size battery bank is listed below in each of the amp hour configurations in 12 volts up to 48 volts, simply click "buy now" to order and collect from one of our warehouses 4 working days later, or if you would like the bank delivered add in the comments column your address in full and I will email you a separate freight invoice. We load your bank on to your trailer, truck or utility with a forklift, the batteries are secured on a pallet for your safety, note you must use ratchet tie down straps to secure your load, ropes are no longer legal to use. Standard utilities can only carry 400 kilos so be aware of that limit unless modifications have been made.
If you have any queries about battery transport please contact us on 0499 074 493 or mailto:raps@mail.com for assistance.

There are 3 groups of battery banks below pre set in common voltages for your convenience, simply click on the
"add to cart" button add any delivery instructions at checkout and we will do the rest.


Group 1.    930 Amp Hour C100 Battery Banks.

12 volt x 930 Amp Hour C100 Battery Bank.
930 amp hour x 12 volts.
Each battery dimension is 125 mm Deep x 158 mm Wide x 510 mm High.
Individual battery weight is x 29.8 kilos.
Total bank weight is 178.80 kilograms, allow an extra 30 kilograms if transported with pallet.

    Specifications:
    C100 to 1.80 Volts per cell 930,      C20 to 1.85 VPC  590,      C10 to 1.80 VPC  565,      C5 to 1.70 VPC  525, 
    Internal resistance 0.000387       Short circuit current amps 5156.76.  1 year manufacturer warranty, 2 years operational pro rata warranty*
    * records booklet supplied by RAPS must be filled in to show battery voltage and specific gravity tests have been done as per the schedule during  the pro rata period.
A$
1,945.00    

24 volt x 930 Amp Hour C10 Battery Bank.
930 amp hour x 24 volts.
Each battery dimension is 125 mm Deep x 158 mm Wide x 510 mm High.
Individual battery weight is x 29.8 kilos.
Total bank weight is 357.60 kilograms, allow an extra 30 kilograms if transported with pallet.

    Specifications: 
    C100 to 1.80 Volts per cell 930,      C20 to 1.85 VPC  590,      C10 to 1.80 VPC  565,     C5 to 1.70 VPC  525,    
    Internal resistance 0.000387,      Short circuit current amps 5156.76.  1 year manufacturer warranty, 2 years operational pro rata warranty*
    * records booklet supplied by RAPS must be filled in to show battery voltage and specific gravity tests have been done as per the schedule during  the pro rata period.
A$
3,516.00    

48 volt x 930 Amp Hour C100 Battery Bank.
930 amp hour x 24 volts.
Each battery dimension is 125 mm Deep x 158 mm Wide x 510 mm High.
Individual battery weight is x 29.8 kilos.
Total bank weight is 715.20 kilograms, allow an extra 30 kilograms if transported with pallet. 
   
   
Specifications:
   
C100 to 1.80 Volts per cell 930,      C20 to 1.85 VPC  590,      C10 to 1.80 VPC 565,     C5 to 1.70 VPC 525,    
    Internal resistance 0.000387,      Short circuit current amps 5156.76.  1 year manufacturer warranty, 2 years operational pro rata warranty*
    * records booklet supplied by RAPS must be filled in to show battery voltage and specific gravity tests have been done as per the schedule during  the pro rata period 

 
A$
7,032.00    

Group 2.   1100 Amp Hour C100 Battery Banks.




Group3.     1600 Amp Hour C10 Battery Banks.

12 volt x 1600 Amp Hour C100 Battery Bank.
 1600 amp hour x 12 volts.                                         
 Each battery dimension is 141 mm Deep x 158 mm Wide x 510 mm High.
 Individual battery weight is 44.9 kilos.
 Total bank weight is 269.40 kilograms, allow an extra 50 kilograms if transporting in a pallet crate.

     Specifications: 
     C100 to 1.80 Volts Per Cell 1600,     C20 to 1.85 VPC 1034,     C10 to 1.80 VPC 967,     C5 to 1.70 VPC 900.
     Internal resistance 0.000235,     Short circuit current amps 8749.40.  1 year manufacturer warranty, 2 years operational pro rata warranty*
      * records booklet supplied by RAPS must be filled in to show battery voltage and specific gravity tests have been done as per the schedule during the pro rata period 
A$
3,072.00    

24 volt x 1600 Amp Hour C100 Battery bank.
1600 amp hour x 24 volts.
Each battery dimension is 141 mm Deep x 158 mm Wide x 510 mm High.
Individual battery weight is 44.9 kilos.
Total bank weight is 538.88 kilograms, allow an extra 50 kilograms if transporting in a pallet crate. 

    
Specifications:          
 C100 to 1.80 Volts Per Cell 1600,     C20 to 1.85 VPC 1034,     C10 to 1.80        VPC 967,     C5 to 1.70 VPC 900.
Internal resistance 0.000235,     Short circuit current amps 8749.40.  1 year manufacturer warranty, 2 years operational pro rata warranty*
* records booklet supplied by RAPS must be filled in to show battery voltage and specific gravity tests have been done as per the schedule during the pro rata period.
A$
5,999.00    

48 volt x 1600 Amp Hour C100 Battery Bank.
1600 amp hour x 48 volts.
Each battery dimension is 141 mm Deep x 158 mm Wide x 510 mm High.
Individual battery weight is 44.9 kilos.
Total bank weight is 1078.80 kilograms, allow an extra 50 kilograms if transporting in a pallet crate.

     Specifications:                                              
C100 to 1.80 Volts Per Cell 1600,     C20 to 1.85 VPC 1034,     C10 to 1.80 VPC 967,    
C5 to 1.70 VPC 900.
Internal resistance 0.000235,     Short circuit current amps 8749.40.  1 year manufacturer warranty, 2 years operational pro rata warranty*
* records booklet supplied by RAPS must be filled in to show battery voltage and specific gravity tests have been done as per the schedule during the pro rata period 
A$
11,999.00    

If you would like to download a full specification sheet on our Solar Cycle Sun King Batteries click on the link below

sun_king_blank_-_mk_3.pdf
File Size: 98 kb
File Type: pdf
Download File


PLEASE NOTE: INDIVIDUAL BATTERIES ARE VERY HEAVY AND REQUIRE TWO PEOPLE TO LIFT, BATTERY BANKS LIFTED IN ONE PIECE REQUIRE A FORKLIFT THAT MUST BE OPERATED BY A QUALIFIED ACCREDITED FORKLIFT OPERATOR WITH APPROPRIATE CURRENT INSURANCE AND LIABILITY POLICIES. NEVER
TAKE THE TRANSPORT OF BATTERIES FOR GRANTED, ENSURE THAT THEY ARE TIGHTLY SECURED WITH RATCHET STRAPS OF APPROPRIATE CAPACITY ROPES, OCTOPUSS STRAPS, BANDS AND THE LIKE ARE NOT ALLOWED BY LAW. IT IS YOUR RESPONSIBILITY TO ENSURE SAFE TRANSPORT OF BATTERIES THAT ARE COLLECTED FROM ANY OF OUR WAREHOUSES. OUR LIABILITY STOPS ONCE LOADED ON TO YOUR TRANSPORT. RAPS ACCEPTS NO RESPONSIBILITY FOR ANY DAMAGE OR DEATH CAUSED BY INCORRECT TRANSPORT OR MOVING OF BATTERIES AND ASSOCIATED TRANSPORT.
Powered by Create your own unique website with customizable templates.